Ventricule gauche
EPSS
ITV LVOT
Valves
Sténose aortique
Insuffisance mitrale
Ventricule droit
TAPSE
Trans Annular Plane Excursion represents a measure of the RV longitudinal function and measured using M-mode. The cursor should have proper alignment on the apical 4 chamber view and along the direction of the tricuspid lateral annulus. The drawbacks is that it depends on angle of measurement and is only partially representative of RV global function. A value less than 17mm is highly suggestive of RV systolic dysfunction.
Signe de McConnell
McConnell’s sign is a distinct echocardiographic finding described in patients with an acute massive PE with: - akinesia of the mid free wall - normal motion at the apex
Sensibilité 22%, spécificité 97% (aussi si ischémie/infarctus du VD)